Airworthiness Directives; Bombardier, Inc., Airplanes

AD 2024-23115 Published 2024-10-08 1 model 127 US-registered tails affected Federal Register ↗

Abstract

The FAA is adopting a new airworthiness directive (AD) for certain Bombardier, Inc., Model BD-700-2A12 airplanes. This AD was prompted by a report indicating that the fan in a transformer rectifier unit (TRU) can become inoperative in a manner that is not detectable by the fan monitoring circuit. This AD requires replacement of the existing TRU Number 2 with a new part number that incorporates a correction to the fan and the monitoring circuit. This AD also prohibits the installation of affected parts. The FAA is issuing this AD to address the unsafe condition on these products.

Applicability

Aircraft makes and models this AD applies to, sorted by US-registered fleet size.

Federal Register text

Verbatim from the Federal Register publication — required actions, compliance times, parts/serial numbers, and methods of compliance. The Federal Register is the legally binding document; this rendering is for readability. Cite: 89 FR 81333.

[Federal Register Volume 89, Number 195 (Tuesday, October 8, 2024)] [Rules and Regulations] [Pages 81333-81335] From the Federal Register Online via the Government Publishing Office [www.gpo.gov] [FR Doc No: 2024-23115]

-----------------------------------------------------------------------

DEPARTMENT OF TRANSPORTATION

Federal Aviation Administration

14 CFR Part 39

[Docket No. FAA-2024-0227; Project Identifier MCAI-2023-00886-T; Amendment 39-22838; AD 2024-18-04] RIN 2120-AA64

Airworthiness Directives; Bombardier, Inc., Airplanes

AGENCY: Federal Aviation Administration (FAA), DOT.

ACTION: Final rule.

-----------------------------------------------------------------------

SUMMARY: The FAA is adopting a new airworthiness directive (AD) for certain Bombardier, Inc., Model BD-700-2A12 airplanes. This AD was prompted by a report indicating that the fan in a transformer rectifier unit (TRU) can become inoperative in a manner that is not detectable by the fan monitoring circuit. This AD requires replacement of the existing TRU Number 2 with a new part number that incorporates a correction to the fan and the monitoring circuit. This AD also prohibits the installation of affected parts. The FAA is issuing this AD to address the unsafe condition on these products.

DATES: This AD is effective November 12, 2024. The Director of the Federal Register approved the incorporation by reference of a certain publication listed in this AD as of November 12, 2024.

View on Federal Register ↗