Skip to content

Failure analysis of a Stirling engine heat pipe

NASA NTRS · Technical Memorandum (TM) · 19890010856 · Published 2019-06-24 · Legacy CDMS · 3 authors

Abstract and citation only, verbatim from NASA NTRS; full text lives there. All credit to the authors and Legacy CDMS.

Abstract

Failure analysis was conducted on a heat pipe from a Stirling Engine test rig which was designed to operate at 1073 K. Premature failure had occurred due to localized overheating at the leading edge of the evaporator fin. It was found that a crack had allowed air to enter the fin and react with the sodium coolant. The origin of the crack was found to be located at the inner surface of the Inconel 600 fin where severe intergranular corrosion had taken place.

Authors

  • Moore, Thomas J. NASA Lewis Research Center
  • Cairelli, James E. NASA Lewis Research Center
  • Khalili, Kaveh Stirling Thermal Motors, Inc., Ann Arbor

Citation

Moore, Thomas J., Cairelli, James E., Khalili, Kaveh (2019). Failure analysis of a Stirling engine heat pipe. Legacy CDMS. NASA NTRS ID 19890010856. https://ntrs.nasa.gov/citations/19890010856 ↗