Skip to content

ATL87LA151

1987-05-27 · WINDER, Georgia, United States · None · 1 aircraft · Status: Completed

Airport WDR

N18HB has since been reassigned. It is now registered to a different aircraft (CESSNA 180), which was not involved in this event.

Aircraft involved

Factual narrative

THE PLT REPORTED EXPERIENCING A COMPLETE ELECTRICAL FAILURE SHORTLY AFTER TAKEOFF. ALL SYSTEMS WERE SHUT DOWN AND THE PLT DECLARED AN EMERGENCY. THE FLIGHT DESCENDED TO VISUAL CONDITIONS FOR A LANDING AT WINDER. THE PLT SHUT DOWN THE ENGINE AND ATTEMPTED A NO POWER LANDING. THE ACFT STALLED ABOUT 15 FEET ABOVE THE GROUND. THE INVESTIGATION DISCLOSED THAT AN ALTERNATOR BRUSH WAS DISLODGED FROM IT'S NORMALLY INSTALLED POSITION. THE ENGINE OPERATED NORMALLY. THE ELECTRICAL FAILURE DID NOT NECESSITATE STALLING THE ACFT 20 FEET ABOVE THE GROUND. Source: NTSB Aviation Accident Database (Pre-2008 Archive) Retrieved: 2026-02-12

Verbatim from NTSB's published report. Source file NTSB_1987_ATL87LA151.txt. Findings + structured fields enriched from FAA avall.mdb. Full investigation docket on data.ntsb.gov ↗.

Related research

Matched on aircraft type or causal vocabulary (stall). All research papers