Skip to content

ATL92IA025

1991-11-20 · ATLANTA, Georgia, United States · None · 1 aircraft · Status: Completed

Airport ATL

Aircraft involved

Probable cause & findings

A SHORT IN AN ELECTRICAL CONNECTOR WHICH RESULTED IN ITS FAILURE. THE REASON FOR THE SHORT WAS NOT DETERMINED. A FACTOR WAS THE IMPROPER INSTALLATION OF THE CONNECTOR BY AN UNKNOWN MAINTENANCE PERSON.

Factual narrative

SHORTLY AFTER LIFTOFF A PASSENGER IN ROW 18 REPORTED OBSERVING FLAMES COMING FROM THE OVERHEAD AREA ON THE RIGHT SIDE OF THE AIRPLANE. THE FLIGHT ATTENDANT SUPPRESSED THE REPORTED AREA WITH A HALON FIRE EXTINGUISHER AND REPORTED THE INCIDENT TO THE FLIGHT DECK. HOWEVER, THE FLIGHT ATTENDANT DID NOT REPORT SEEING FLAMES. AN EMERGENCY LANDING WAS MADE AT THE DEPARTURE AIRPORT WITHOUT FURTHER INCIDENT. EXAMINATION OF THE OVERHEAD AREA AROUND ROW 18 REVEALED THAT THE CANNON PLUG CONNECTOR ADJACENT TO THE LIGHT ASSEMBLY HAD SHORTED. SUBSEQUENT EXAMINATIONS OF THE CONNECTOR REVEALED THAT PINS IN THE MATING HALVES OF THE CONNECTOR WERE DAMAGED, AND APPEARED TO HAVE OCCURED WHEN A PREVIOUS CONNECTION WAS ATTEMPTED. RESEARCH EFFORTS TO DUPLICATE THE CONNECTOR FAILURE MODE FAILED. A REVIEW OF THE OPERATORS MAINTENANCE RECORDS FAILED TO DISCLOSE IF ANY MAINTANANCE HAD BEEN CONDUCTED IN THE AREA OF THE CONNECTOR. HOWEVER, THE OPERATOR COULD NOT VERIFY THAT THE CONNECTOR AND AFFECTED AREAS WERE NEVER SERVICED DURING A PREVIOUS STOPOVER Source: NTSB Aviation Accident Database (Pre-2008 Archive) Retrieved: 2026-02-12

Verbatim from NTSB's published report. Source file NTSB_1991_ATL92IA025.txt. Findings + structured fields enriched from FAA avall.mdb. Full investigation docket on data.ntsb.gov ↗.

Related research

Matched on aircraft type or causal vocabulary (stall, maintenance). All research papers