ERA11IA091
2010-12-04 · Boston, Massachusetts, United States · None · 1 aircraft · Status: Completed
Airport MA39
Aircraft involved
Probable cause & findings
Improper installation of wiring associated with a medical cabinet interior, which resulted in chafing and a subsequent in-flight fire. Contributing to the incident was inadequate maintenance procedures for continued airworthiness.
Factual narrative
On December 4, 2010, about 0900 eastern standard time, a Eurocopter Deutschland GMBH, MBB-BK117-C1, N271NE, sustained minor damage when it experienced an in-flight electrical fire, while on approach to the Brigham & Women's Hospital Heliport (MA39), Boston, Massachusetts. The helicopter was owned by New England Life Flight, doing business as Boston MedFlight, and operated by ERA Med LLC, as an air ambulance flight conducted under the provisions of 14 Code of Federal Regulations Part 135. The airline transport pilot, flight nurse, flight paramedic, and patient were not injured. Visual meteorological conditions prevailed and a company flight plan had been filed for the flight that departed from Oak Bluffs, Massachusetts. According to the flight nurse, the helicopter was on final approach to land, when she noticed "a smell" followed by smoke and flames emanating from the suction control mounted on the left side of the cabin. She notified the pilot and discharged a fire extinguisher, which extinguished the fire. The pilot landed the helicopter without further incident. He subsequently noted obvious fire damage on the left cabin wall near the suction device control switch and the liquid oxygen gauge. Post incident inspection by a Federal Aviation Administration (FAA) inspector revealed fire damage on the face of the overhead medical cabinet around the vacuum control switch. The cabinet was part of a medical interior that was installed per a supplemental type certificate (STC) during May 2003, and housed a vacuum regulator, vacuum pump switch, liquid oxygen quantity indicator and 120-volt alternating current (AC) electrical outlets. A sheathed wiring bundle for the 120-volt AC power outlet mounted in the aft end of the cabinet displayed chafing damage and arching consistent with rubbing on the metal housing for the vacuum control switch. In addition, an approximate 2-inch portion of composite material, which surrounded the switch, was consumed by fire. Additional examination was performed by an FAA inspector, who reported that the wiring was installed without adequate clearance or support to prevent it from chafing on the switch housing. The electrical power to the outlets was supplied by a KGS Electronics SPS-1607A medical inverter system, which was installed per an STC during June 2003. Review of the instructions for continued airworthiness associated with the medical cabinet installation did not reveal any required inspections of the associated wiring harnesses for general condition or chafing. The helicopter was maintained under an FAA approved inspection program and had been operated for approximately 254 hours since its most recent 300 hour/12 month inspection, which was performed on August 12, 2010. Item 24 on the inspection checklist included: "Visually inspect inverter and mounting for damage, security and electrical connections" and "Test medical inverter for proper operation," with a reference to the KGS-SPS-1607A Removal/Installation Manual. Review of the KGS-SPS-1607A Removal/Installation Manual revealed instructions for removal and installation. Under instructions for maintenance, the manual stated "No regular periodic maintenance is required for this product. Service is required only when a malfunction is detected. Maintenance consists of removal and replacement." An FAA check of service difficulty reports for the BK117 did not reveal any previous instances of fires associated with the medical cabinet installation. FAA Advisory Circular AC65-15A, Airframe and Powerplant Mechanics Airframe Handbook, Chapter 11, Aircraft Electrical Systems, Protection Against Chafing, stated in part: "Wires and wire groups should be protected against chafing or abrasion in those locations where contact with sharp surfaces or other wires would damage the insulation. Damage to the insulation can cause short circuits, malfunction, or inadvertent operation of equipment…." During the air ambulance flight, the helicopter was on final approach to land when smoke and flames were observed emanating from the suction control mounted on the left side of the cabin. The fire was subsequently extinguished, and the pilot landed the helicopter without further incident. Postincident examination revealed fire damage on the face of an overhead medical cabinet that was part of a medical interior installed about 7.5 years prior to the incident per a supplemental type certificate. A sheathed wiring bundle for a 120-volt alternating current power outlet mounted in the aft end of the cabinet displayed chafing damage and arcing consistent with rubbing on the metal housing for the vacuum control switch. The wiring was installed without adequate clearance or support to prevent it from chafing on the switch housing. The helicopter was maintained under an approved inspection program; however, review of the instructions for continued airworthiness associated with the medical cabinet installation did not reveal any required inspections of the associated wiring harnesses for general condition or chafing. Source: NTSB Aviation Accident Database Retrieved: 2026-02-12
NTSB Findings
FAA avdata. C = Cause, F = Factor.
- C Aircraft-Aircraft systems-Equipment/furnishings-Equ/fur sys wiring-Fatigue/wear/corrosion - C
- C Personnel issues-Task performance-Maintenance-Modification/alteration-Maintenance personnel - C
- F Aircraft-Aircraft systems-Equipment/furnishings-Equ/fur sys wiring-Related maintenance info - F
Verbatim from NTSB's published report. Source file
NTSB_2010_ERA11IA091.txt.
Findings + structured fields enriched from FAA avall.mdb.
Full investigation docket on
data.ntsb.gov ↗.
Search this event elsewhere
External sources are reported, not agency: signal that something happened, not fact about what happened.
- TallyAero Live Wire Aviation press
- NTSB CAROL Agency ↗
- NTSB Docket Agency ↗
- Aviation Safety Network Aviation press ↗
- Kathryn's Report Aviation press ↗
- Aviation Herald Aviation press ↗
- AVweb Aviation press ↗
- Pilots of America Community ↗
- Reddit /r/flying Community ↗
- FlightAware Aviation press ↗
- AOPA accident database Aviation press ↗
- Google News News ↗
- DuckDuckGo News ↗
Related research
Matched on aircraft type or causal vocabulary (stall, maintenance). All research papers
- Embry-Riddle Scholarly Commons 2023 · Conference paper The Value of Strong Partnerships to Build a Successful Aviation Maintenance Career Pathway Program for Transitioning Military Service Members
The aerospace industry is competing with other industries for a qualified workforce, and many of those competing industries are investing heavily in creating workforce development pipelines.
- Embry-Riddle Scholarly Commons 2026 · Journal article (IJAAA) From Reactive to Predictive: A hybrid Trust-Mediated Adoption Framework for Data-Driven Maintenance in Distributed-Authority Aviation Environments
Modern aviation maintenance operates within increasingly data-intensive technological environments, yet the operational integration of predictive maintenance into routine decision-making remains incon…
- NASA NTRS 2026 · Conference Paper Computational Analysis of Steady State Aerodynamics of Transonic Truss-Braced Wing Configuration in Deep Stall
This study presents a computational investigation of steady state aerodynamics of the Subsonic Ultra-Green Aircraft Research (SUGAR) Transonic Truss-Braced Wing (TTBW) configuration over a wide range …
- Semantic Scholar 2026 · Article (Reliability Engineering & System Safety) Understanding human error in military aviation maintenance: The role of Performance shaping factors, cognitive workload and error orientation
- Semantic Scholar 2025 · Article (Applied Sciences) Decision-Making Framework for Aviation Safety in Predictive Maintenance Strategies
The implementation of predictive maintenance (PM) in aviation presents unique challenges due to strict safety requirements, complex operational environments, and regulatory constraints.
- Semantic Scholar 2024 · Article (Defence Science Journal) Modelling of Human Factors in Aviation Maintenance Using HFACS ME Human Factors Analysis and Classification System Maintenance Extension and Bayesian Network
Aircraft maintenance is a complex task involving a skilled human workforce, spare parts, and various other resources. Human factors are an inherent element of the human workforce.