Skip to content

Atlas / NTSB / FTW96LA402

NTSB CAROL · Event

Event FTW96LA402

1996-08-23 TELLURIDE, Colorado, United States Airport · TEX None 1 aircraft Status: Completed

Registry · N757QT

FAA Aircraft Registry record.

Make / Model

CESSNA TR182

Year of manufacture

1979 · 17 years old at event

Engine

LYCOMING 0-540 SERIES (250 hp)

Seats / Engines

4 seats · 1 engine

Last airworthiness date

19790827

ADS-B equipped

Yes — Mode-S AA357A

Registrant of record

MOXLEY EQUIPMENT CO INC

Source: FAA Aircraft Registry (releasable master file).

Aircraft involved

Probable cause & findings

failure of the generator control unit (GCU), which resulted in a total electrical failure and failure of the main landing gear to lock in place.

Factual narrative

On August 23, 1996, approximately 1840 mountain daylight time, a Cessna TR182, N757QT, was substantially damaged when the main landing gear collapsed during landing at Telluride, Colorado. The private pilot was not injured. Visual meteorological conditions prevailed, and no flight plan was filed for the personal flight that originated at Loveland, Colorado, on August 23, 1996, approximately 1630. According to the pilot, when he was 10 miles from the airport, he called for an airport advisory but got no reply. When he was 5 miles from the airport, he lowered the landing gear. The pilot said there was a total electrical failure, and he but could not recall if he observed a GEAR DOWN AND LOCKED indication. He attempted to reset the alternator/voltage regulator circuit breaker but to no avail. Upon landing, the left and right main landing gears collapsed; the nose landing gear was down and locked. This mishap was reported on the date of the occurrence as an incident. On September 23, 1996, the Denver Field Office of the National Transportation Safety Board was advised by the FAA's Salt Lake City, Utah, Flight Standards District Office that an airworthiness inspector had examined the airplane and found that the left horizontal stabilizer forward and aft spars were bent. A spokesman for West Star Aviation, a repair facility in Grand Junction, Colorado, reported the generator control unit (GCU) had failed. The unit was sent to Precision Airmotive in Everett, Washington, for examination and testing. A company spokesman identified the GCU as one of their products and confirmed the unit had failed. As the pilot lowered the landing gear, there was a total electrical failure. He said he could not recall if he observed a GEAR DOWN AND LOCKED indication. He attempted to reset the alternator/voltage regulator circuit breaker, but to no avail. During the landing, the main landing gear collapsed, but the nose landing gear remained down and locked. The airplane skidded off the runway, damaging the left horizontal stabilizer forward and aft spars. Postaccident examination by a repair facility (and later confirmed by the manufacturer) disclosed the generator control unit (GCU) had failed. Source: NTSB Aviation Accident Database (Pre-2008 Archive) Retrieved: 2026-02-12

Verbatim from NTSB's published report. Source file NTSB_1996_FTW96LA402.txt. Findings + structured fields enriched from FAA avall.mdb. Full investigation docket on data.ntsb.gov ↗.