Skip to content

SEA99LA025

1998-12-25 · BELLINGHAM, Washington, United States · None · 1 aircraft · Status: Completed

Airport BLI

Current FAA registration · N2355Y

Make / Model
CESSNA 177
Year of manufacture
1967 · 31 years old at event
Engine
LYCOMING 0-320 SERIES (180 hp)
Seats / Engines
4 seats · 1 engine
Last airworthiness date
19671023
ADS-B equipped
Yes — Mode-S A21E31

Source: FAA Aircraft Registry (releasable master file).

Aircraft involved

Probable cause & findings

Inadequate preflight planning/preparation, and the pilot's failure to maintain altitude. VFR flight into IMC conditions and cloudy weather conditions were factors.

Factual narrative

On December 25, 1998, about 1845 Pacific standard time, a Cessna 177 Cardinal, N2355Y, registered to and operated by the pilot as a 14 CFR Part 91 pleasure flight, was substantially damaged after colliding with tree tops shortly after departure from the Bellingham Airport (BLI), Bellingham Washington. Night visual meteorological conditions prevailed and no flight plan was filed. The private pilot and his passenger were uninjured. There was no fire, and no report of an ELT actuating. The flight originated from the Bellingham Airport approximately 10 minutes prior to the accident. The pilot stated that shortly after take off, during the ascent, he encountered instrument meteorological conditions at approximately 500 feet above ground level and initiated a turn back to the airport. The pilot stated that "During the turn, I apparently overreacted and increased the bank angle to the extent that it began losing altitude. My instrument scan was poor and I realize now that I was spending too much time looking outside for ground reference." The pilot leveled the wings. However, the airplane continued to descend and collided with tree tops. The pilot was able to continue to the airport and land without further incident. The pilot also stated he did not receive a formal weather briefing from a flight service station and relied solely on the automated weather observing system report at the Bellingham airport. At 1856, the Bellingham automated weather observing system was reporting wind from 350 degrees at eight knots. Visibility was four miles with light rain. The sky condition was reported as a few clouds at 800 feet and overcast at 1,400 feet. The pilot stated that shortly after takeoff, during the ascent, he encountered instrument meteorological conditions at 500 feet AGL, and initiated a turn back to the airport. During the turn, the aircraft lost a considerable amount of altitude and collided with multiple tree tops. The pilot was able to continue to the airport and land without further incident. The pilot stated he did not receive a formal weather briefing from a flight service station and relied solely on the automated surface observation system report at the airport. Source: NTSB Aviation Accident Database (Pre-2008 Archive) Retrieved: 2026-02-12

Verbatim from NTSB's published report. Source file NTSB_1998_SEA99LA025.txt. Findings + structured fields enriched from FAA avall.mdb. Full investigation docket on data.ntsb.gov ↗.