AD 2024-06130
Published 2024-03-25 · 2 models · 51 US-registered tails affected · Federal Register
Airworthiness Directives; The Boeing Company Airplanes Federal Register ↗
Abstract
The FAA proposes to adopt a new airworthiness directive (AD) for certain The Boeing Company Model 777 airplanes. This proposed AD was prompted by a determination that the nitrogen enriched air distribution system (NEADS) cover plate assembly attached to a certain vent stringer in the center wing tank was installed without a designed electrical bond. This proposed AD would require installing electrical bonding and grounding, installing the cover plate assembly with new fasteners, and revising the existing maintenance or inspection program, as applicable, to incorporate new airworthiness limitations. The FAA is proposing this AD to address the unsafe condition on these products.
Applicability · by US fleet size
- BOEING 777F TCDS T00001SE 43 tails
- BOEING 777-200 TCDS T00001SE 8 tails
Federal Register text
Verbatim; the Federal Register publication is the legally binding document. Cite: 89 FR 20555. View on Federal Register ↗
[Federal Register Volume 89, Number 58 (Monday, March 25, 2024)] [Proposed Rules] [Pages 20555-20558] From the Federal Register Online via the Government Publishing Office [www.gpo.gov] [FR Doc No: 2024-06130]
-----------------------------------------------------------------------
DEPARTMENT OF TRANSPORTATION
Federal Aviation Administration
14 CFR Part 39
[Docket No. FAA-2024-0761; Project Identifier AD-2023-01256-T] RIN 2120-AA64
Airworthiness Directives; The Boeing Company Airplanes
AGENCY: Federal Aviation Administration (FAA), DOT.
ACTION: Notice of proposed rulemaking (NPRM).
-----------------------------------------------------------------------
SUMMARY: The FAA proposes to adopt a new airworthiness directive (AD) for certain The Boeing Company Model 777 airplanes. This proposed AD was prompted by a determination that the nitrogen enriched air distribution system (NEADS) cover plate assembly attached to a certain vent stringer in the center wing tank was installed without a designed electrical bond. This proposed AD would require installing electrical bonding and grounding, installing the cover plate assembly with new fasteners, and revising the existing maintenance or inspection program, as applicable, to incorporate new airworthiness limitations. The FAA is proposing this AD to address the unsafe condition on these products.
DATES: The FAA must receive comments on this proposed AD by May 9, 2024.
ADDRESSES: You may send comments, using the procedures found in 14 CFR 11.43 and 11.45, by any of the following methods: Federal eRulemaking Portal: Go to regulations.gov. Follow the instructions for submitting comments. Fax: 202-493-2251. Mail: U.S. Department of Transportation, Docket Operations, M-30, West Building Ground Floor, Room W12-140, 1200 New Jersey Avenue SE, Washington, DC 20590. Hand Delivery: Deliver to Mail address above between 9 a.m. and 5 p.m., Monday through Friday, except Federal holidays. AD Docket: You may examine the AD docket at regulations.gov under Docket No. FAA-2024-0761; or in person at
[[Page 20556]]
Docket Operations between 9 a.m. and 5 p.m., Monday through Friday, except Federal holidays. The AD docket contains this NPRM, any comments received, and other information. The street address for Docket Operations is listed above. Material Incorporated by Reference: For service information, contact Boeing Commercial Airplanes, Attention: Contractual & Data Services (C&DS), 2600 Westminster Boulevard, MC 110-SK57, Seal Beach, CA 90740-5600; telephone 562-797-1717; website myboeingfleet.com. You may view this service information at the FAA, Airworthiness Products Section, Operational Safety Branch, 2200 South 216th Street Des Moines, WA. For information on the availability of this material at the FAA, call 206-231-3195. It is also available at regulations.gov by searching for and locating Docket No. FAA-2024-0761.
FOR FURTHER INFORMATION CONTACT: Anthony Decaro, Aviation Safety Engineer, FAA, 2200 South 216th Street, Des Moines, WA 98198; telephone: 562-627-5374; email: [email protected].