Airworthiness Directives; The Boeing Company Airplanes

AD 2012-2973 Published 2012-02-17 1 model 169 US-registered tails affected Federal Register ↗

Abstract

We are adopting a new airworthiness directive (AD) for certain The Boeing Company Model 767-200, -300, and -300F series airplanes. This AD was prompted by reports of loss of avionics cooling due to an unserviceable relay installed on a panel as part of the cabin air conditioning and temperature control system (CACTCS). This AD requires doing certain wiring changes, installing a new relay and necessary wiring in the CACTCS, and performing an operational test of the cooling pack system. We are issuing this AD to prevent loss of electrical equipment bay cooling and the overheating of flight deck instruments, which would result in the eventual loss of primary flight displays, an unusually high pilot workload, and depressurization of the cabin.

Applicability

Aircraft makes and models this AD applies to, sorted by US-registered fleet size.

Federal Register text

Verbatim from the Federal Register publication — required actions, compliance times, parts/serial numbers, and methods of compliance. The Federal Register is the legally binding document; this rendering is for readability. Cite: 77 FR 9518.

[Federal Register Volume 77, Number 33 (Friday, February 17, 2012)] [Rules and Regulations] [Pages 9518-9520] From the Federal Register Online via the Government Publishing Office [www.gpo.gov] [FR Doc No: 2012-2973]

======================================================================= -----------------------------------------------------------------------

DEPARTMENT OF TRANSPORTATION

Federal Aviation Administration

14 CFR Part 39

[Docket No. FAA-2011-0725; Directorate Identifier 2011-NM-065-AD; Amendment 39-16943; AD 2012-03-02] RIN 2120-AA64

Airworthiness Directives; The Boeing Company Airplanes

AGENCY: Federal Aviation Administration (FAA), DOT.

ACTION: Final rule.

-----------------------------------------------------------------------

SUMMARY: We are adopting a new airworthiness directive (AD) for certain The Boeing Company Model 767-200, -300, and -300F series airplanes. This AD was prompted by reports of loss of avionics cooling due to an unserviceable relay installed on a panel as part of the cabin air conditioning and temperature control system (CACTCS). This AD requires doing certain wiring changes, installing a new relay and necessary wiring in the CACTCS, and performing an operational test of the cooling pack system. We are issuing this AD to prevent loss of electrical equipment bay cooling and the overheating of flight deck instruments, which would result in the eventual loss of primary flight displays, an unusually high pilot workload, and depressurization of the cabin.

DATES: This AD is effective March 23, 2012. The Director of the Federal Register approved the incorporation by reference of certain publications listed in the AD as of March 23, 2012.

ADDRESSES: For service information identified in this AD, contact Boeing Commercial Airplanes, Attention: Data & Services Management, P.O. Box 3707, MC 2H-65, Seattle, Washington 98124-2207; telephone 206- 544-5000, extension 1; fax 206-766-5680; email: [email protected]; Internet https://www.myboeingfleet.com. You may review copies of the referenced service information at the FAA, Transport Airplane Directorate, 1601 Lind Avenue SW., Renton, Washington. For information on the availability of this material at the FAA, call 425-227-1221.

Examining the AD Docket

You may examine the AD docket on the Internet at http://www.regulations.gov; or in person at the Docket Management Facility between 9 a.m. and 5 p.m., Monday through Friday, except Federal holidays. The AD docket contains this AD, the regulatory evaluation, any comments received, and other information. The address for the Docket Office (phone: 800-647-5527) is Document Management Facility, U.S. Department of Transportation, Docket Operations, M-30, West Building Ground Floor, Room W12-140, 1200 New Jersey Avenue SE., Washington, DC 20590.

FOR FURTHER INFORMATION CONTACT: Ana Martinez Hueto, Aerospace Engineer, Cabin Safety and Environmental Systems Branch, ANM-150S, FAA, Seattle Aircraft Certification Office, 1601 Lind Avenue SW., Renton, WA 98057-3356; phone: 425-917-6592; fax: 425-917-6590; email: [email protected].

SUPPLEMENTARY INFORMATION:

Discussion

We issued a notice of proposed rulemaking (NPRM) to amend 14 CFR part 39 to include an AD that would apply to the specified products. That NPRM published in the Federal Register on August 24, 2011 (76 FR 52899). That NPRM proposed to require doing certain wiring changes, installing a new relay and necessary wiring in the CACTCS, and performing an operational test of the cooling pack system.

Comments

We gave the public the opportunity to participate in developing this AD. We have considered the comments received. Boeing supports the NPRM (76 FR 52899, August 24, 2011). American Airlines stated that it is not affected by the NPRM.

Conclusion

We reviewed the relevant data, considered the comments received, and determined that air safety and the public interest require adopting the AD as proposed except for minor editorial changes. We have determined that these minor changes: Are consistent with the intent that was proposed in the NPRM (76 FR 52899, August 24, 2011) for correcting the unsafe condition; and Do not add any additional burden upon the public than was already proposed in the NPRM (76 FR 52899, August 24, 2011).

Costs of Compliance

We estimate that this AD affects 35 airplanes of U.S. registry. We estimate the following costs to comply with this AD:

[[Page 9519]]

Estimated Costs ---------------------------------------------------------------------------------------------------------------- Cost per Cost on U.S. Action Labor cost Parts cost product operators ---------------------------------------------------------------------------------------------------------------- Change wire bundle, install relay, 29 work-hours x $85 per $1,240 $3,705 $129,675 and operational test. hour = $2,465 per relay installation. ----------------------------------------------------------------------------------------------------------------

Authority for This Rulemaking

Title 49 of the United States Code specifies the FAA's authority to issue rules on aviation safety. Subtitle I, section 106, describes the authority of the FAA Administrator. Subtitle VII: Aviation Programs, describes in more detail the scope of the Agency's authority. We are issuing this rulemaking under the authority described in Subtitle VII, Part A, Subpart III, Section 44701: ``General requirements.'' Under that section, Congress charges the FAA with promoting safe flight of civil aircraft in air commerce by prescribing regulations for practices, methods, and procedures the Administrator finds necessary for safety in air commerce. This regulation is within the scope of that authority because it addresses an unsafe condition that is likely to exist or develop on products identified in this rulemaking action.

Regulatory Findings

This AD will not have federalism implications under Executive Order 13132. This AD will not have a substantial direct effect on the States, on the relationship between the national government and the States, or on the distribution of power and responsibilities among the various levels of government. For the reasons discussed above, I certify that this AD: (1) Is not a ``significant regulatory action'' under Executive Order 12866, (2) Is not a ``significant rule'' under the DOT Regulatory Policies and Procedures (44 FR 11034, February 26, 1979), (3) Will not affect intrastate aviation in Alaska, and (4) Will not have a significant economic impact, positive or negative, on a substantial number of small entities under the criteria of the Regulatory Flexibility Act.

List of Subjects in 14 CFR Part 39

Air transportation, Aircraft, Aviation safety, Incorporation by reference, Safety.

Adoption of the Amendment

Accordingly, under the authority delegated to me by the Administrator, the FAA amends 14 CFR part 39 as follows:

PART 39--AIRWORTHINESS DIRECTIVES

0 1. The authority citation for part 39 continues to read as follows:

Authority: 49 U.S.C. 106(g), 40113, 44701.

Sec. 39.13 [Amended]

0 2. The FAA amends Sec. 39.13 by adding the following new airworthiness directive (AD):

2012-03-02 The Boeing Company: Amendment 39-16943; Docket No. FAA- 2011-0725; Directorate Identifier 2011-NM-065-AD.

(a) Effective Date

This AD is effective March 23, 2012.

(b) Affected ADs

None.

(c) Applicability

This AD applies to The Boeing Company Model 767-200 and -300 series airplanes, certificated in any category, as identified in Boeing Special Attention Service Bulletin 767-21-0246, dated January 7, 2011; and Model 767-300F series airplanes, certificated in any category, as identified in Boeing Special Attention Service Bulletin 767-21-0234, dated August 6, 2009.

(d) Subject

Joint Aircraft System Component (JASC)/Air Transport Association (ATA) of America Code 21: Air conditioning.

(e) Unsafe Condition

This AD results from reports of loss of avionics cooling due to an unserviceable relay installed on a panel as part of the cabin air conditioning and temperature control system (CACTCS). We are issuing this AD to prevent loss of electrical equipment bay cooling and the overheating of flight deck instruments, which would result in the eventual loss of primary flight displays, an unusually high pilot workload, and depressurization of the cabin.

(f) Compliance

Comply with this AD within the compliance times specified, unless already done.

(g) Installation of New Relay and Wiring Bundle

Within 72 months after the effective date of this AD: Change the wire bundle route and wiring, install a new relay and applicable wiring in the CACTCS, and do an operational test of the cooling pack system, in accordance with the Accomplishment Instructions of the service information specified in paragraph (g)(1) or (g)(2) of this AD, as applicable. (1) For Model 767-200 and 767-300 series airplanes: Boeing Special Attention Service Bulletin 767-21-0246, dated January 7, 2011. (2) For Model 767-300F series airplanes: Boeing Special Attention Service Bulletin 767-21-0234, dated August 6, 2009.

(h) Alternative Methods of Compliance (AMOCs)

(1) The Manager, Seattle Aircraft Certification Office (ACO), FAA, has the authority to approve AMOCs for this AD, if requested using the procedures found in 14 CFR 39.19. In accordance with 14 CFR 39.19, send your request to your principal inspector or local Flight Standards District Office, as appropriate. If sending information directly to the manager of the ACO, send it to the attention of the person identified in the Related Information section of this AD. Information may be emailed to: [email protected]. (2) Before using any approved AMOC, notify your appropriate principal inspector, or lacking a principal inspector, the manager of the local flight standards district office/certificate holding district office.

(i) Related Information

For more information about this AD, contact Ana Martinez Hueto, Aerospace Engineer, Cabin Safety and Environmental Systems Branch, ANM-150S, FAA, Seattle Aircraft Certification Office, 1601 Lind Avenue SW., Renton, WA 98057-3356; phone 425-917-6592; fax 425-917- 6590; email: [email protected].

(j) Material Incorporated by Reference

(1) You must use the following service information to do the actions required by this AD, unless the AD specifies otherwise. The Director of the Federal Register approved the incorporation by reference (IBR) of the following service information under 5 U.S.C. 552(a) and 1 CFR part 51: (i) Boeing Special Attention Service Bulletin 767-21-0246, dated January 7, 2011. (ii) Boeing Special Attention Service Bulletin 767-21-0234, dated August 6, 2009. (2) For service information identified in this AD, contact Boeing Commercial Airplanes, Attention: Data & Services Management, P.O. Box 3707, MC 2H-65, Seattle, Washington 98124-2207; telephone 206-544-5000, extension 1; fax 206-766-5680; email [email protected]; Internet https://www.myboeingfleet.com. (3) You may review copies of the referenced service information at the FAA, Transport Airplane Directorate, 1601 Lind Avenue SW., Renton, Washington. For

[[Page 9520]]

information on the availability of this material at the FAA, call 425-227-1221. (4) You may also review copies of the service information that is incorporated by reference at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal-register/cfr/ibr-locations.html.

Issued in Renton, Washington, on January 26, 2012. Kalene C. Yanamura, Acting Manager, Transport Airplane Directorate, Aircraft Certification Service. [FR Doc. 2012-2973 Filed 2-16-12; 8:45 am] BILLING CODE 4910-13-P